Technical reference / nominal factory configuration

PulseBrick data sheet.

A fixed-function, air-cooled ultrashort pulse laser source for OEM integration. The values below describe the current nominal configuration, with their definitions and reference conditions.

Data sheet · Release 1 · 19 October 2026. Request configuration-specific integration documentation from our team.

Optical configuration

Nominal values.
Defined references.

The supplied laser’s test report identifies its actual operating point, measured results and test conditions. Nominal values are not a substitute for that record or for configuration-specific acceptance limits.

PulseBrick nominal factory configuration · data sheet Release 1, 19 October 2026
ParameterNominal valueDefinition / reference
Average output power10 WFactory output setpoint. Refer to the unit report for measured output.
Pulse energy25 µJNominal mean at 400 kHz and 10 W.
Pulse repetition rate400 kHzNominal operating point; no customer-adjustable rate range is specified.
Pulse duration800 fsNominal final output. Measurement definition and conditions belong to the unit report.
Central wavelength515 nmStandard output wavelength.
Beam waist diameter2 mm1/e² intensity diameter; waist located 100 mm beyond the output aperture.
Beam qualityM² < 1.5Current specification. Use the unit report for measured results and applicable conditions.

This table contains the nominal operating configuration. Separate worst-case safety-calculation assumptions are not operating settings or advertised performance.

Integration basis

Source, controls
and installation.

PulseBrick is intended for qualified integration into an OEM machine or optical system. Use the approved configuration-specific drawings and instructions for detailed design and commissioning.

Nominal integration configuration. Use the configuration-specific documentation supplied for your unit for detailed design and commissioning.
ItemCurrent configurationIntegration reference
Laser head17.5 kgFour platform mounting feet and front accessory mounting interface. Approved drawings define mounting, handling and beam datums.
CoolingAir cooledPreserve ventilation and the approved installation clearances.
Routine user controlsOn/off; pulse energy adjustable up to 25 µJ25 µJ nominal at 400 kHz and 10 W. The unit report defines calibrated output; intermediate commands need not produce a linear optical response.
Intended analogue interfaceDifferential 0–10 V commandStandard calibration target: 10 W at 10 V, subject to factory calibration and verification.
PowerTwo supplied 24 V adaptersSeparate housekeeping and high-power roles. Adapter capacity does not describe measured laser consumption.
Optional monitoringFactory-configured digital statusAvailability and interface details depend on the supplied configuration.
Intended useClass 4 OEM laser sourceQualified integration and application-specific protective measures are required for the completed machine.

Nominal operating environment: clean indoor, non-condensing operation at 15–27 °C. Confirm dimensions, mounting limits, cooling clearances, environmental limits, electrical behaviour and protective recovery in the configuration-specific documentation for your unit.

Routine output commands do not provide safe access. The completed machine requires its own assessment of beam delivery, focusing, materials, guarding, interlocks and process hazards.

Specify the configuration together.

Sales and integration: sales@pulsebrick.com
Technical documentation and service: service@pulsebrick.com